M-SYSTEMS Industrial Partner

M3LU2 - M-Systems M3LU2 M3-UNIT Series PC Programmable Signal Conditioner; Universal Transmitter...

larger image

Request Quote
For Price
Part Number:
M3LU2
Model Number:
M3LU2
Make:
M-SYSTEMS
Lead Time:
Available
Qty In Stock:
Available

M-Systems M3LU2 M3-UNIT Series PC Programmable Signal Conditioner; Universal Transmitter (field- and PC-configurable) Simple Type: Signal Conditioning

Signal conditioners convert a field signal from various sensors into standard signal suitable for processing in PLC, DCS or PC-based systems. They are also used to boost a signal to increase load drive capability, to isolate a signal to stop ground loops. More than 75000 combinations of process signal I/O, power input and mounting configuration are selectable. Additionally, M-System offers the broadest line of signal splitters available. These thin profile M3-Unit Series are PC Programmable; "ONE-STEP CAL" signal conditioners; programming without needing a PC is also available.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • CE marking
  • Easy ‘One-Step Cal’ calibration using the front three control buttons without needing a PC; PC software is also usable.
  • Front control button function can be locked
  • I/O type and ranges are configurable
  • Universal input: mV, V, mA, T/C, RTD, resistance and potentiometer

Specifications

    General
  • ‘One-Step Cal’ calibration: With I/O type and the full-scale range configured via the internal DIP switches, precise 0 % and 100 % ranges are calibrated via the front control buttons with a help of LED.
  • AC Power input: Approx. 4 VA at 100 V; Approx. 5 VA at 200 V; Approx. 6 VA at 264 V
  • Burnout (other than current or voltage (V) input): Upscale, downscale or no burnout selectable; Also detects wire breakdown and overrange input exceeding the electrical design limit for DC input.
  • Burnout response: Less than or equal to 10 sec
  • Cold junction compensation (T/C): CJC sensor (included) to be attached to the input terminals
  • Cold junction compensation error: ±1.0°C at 0 – 50°C (±1.8°F at 32 – 122°F)
  • Configurator connection: 2.5 dia. miniature jack; RS-232-C level
  • Connection: Removable terminal block
  • DC Power input: Approx. 3 W
  • Dielectric strength: 2000 V AC @1 minute (input to output to power to ground)
  • Housing material: Flame-resistant resin (gray)
  • Insulation resistance: Greater than or equal to 100 M Omega with 500 V DC
  • Isolation: Input to output to power
  • Line voltage effect: ±0.1 % over voltage range
  • Mounting: DIN rail
  • Operating humidity: 30 to 95 %RH (non-condensing)
  • Operating temperature: -25 to +60°C (-13 to +140°F)
  • Over-range output: -15 to +115 % (Negative current output is not available.)
  • PC configurator: (model-M3LUCFG) Via Windows PC connected to the front jack.
  • Response time: Less than or equal to 0.2 sec. (0 – 90%, DC input)
  • Span adjustment: 85 to 115 % (front)
  • Status indicator LED: Tri-color (green/amber/red) LED; Flashing patterns indicate operation status of the transmitter.
  • Temp. coefficient: ±0.015 %/°C [±0.008 %/°F] at -5 to +55°C [23 to 131°F] of max. range
  • Weight: 100 g (3.53 oz)
  • Zero adjustment: -15 to +15 % (front)

 

Applications

  • None Available

Aliases