M3LPA2 - M-Systems M3LPA2 M3-UNIT Series PC Programmable Signal Conditioner; Frequency Transmitter...
Request Quote
For Price
- Part Number:
- M3LPA2
- Model Number:
- M3LPA2
- Make:
- M-SYSTEMS
- Lead Time:
- Available
- Qty In Stock:
- Available
M-Systems M3LPA2 M3-UNIT Series PC Programmable Signal Conditioner; Frequency Transmitter (field- and PC-configurable) Simple Type: Signal Conditioning
Signal conditioners convert a field signal from various sensors into standard signal suitable for processing in PLC, DCS or PC-based systems. They are also used to boost a signal to increase load drive capability, to isolate a signal to stop ground loops. More than 75000 combinations of process signal I/O, power input and mounting configuration are selectable. Additionally, M-System offers the broadest line of signal splitters available. These thin profile M3-Unit Series are PC Programmable; "ONE-STEP CAL" signal conditioners; programming without needing a PC is also available.
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Both input and output type and range are configurable
- CE marking
- Converts the output from a pulse-type transducer into a standard process signal
- Easy ‘One-Step Cal’ calibration using the front three control buttons without needing a PC; PC software is also usable.
- Front control button function can be locked
- Sensor excitation
- UL approval
Specifications
- "One-Step Cal’ calibration: With I/O type and the full-scale range configured via the internal DIP switches, precise 0 % and 100 % ranges are calibrated via the front control buttons with a help of LED.
- AC Power input: Approx. 3 VA at 100 V; Approx. 4 VA at 200 V; Approx. 5 VA at 264 V
- Accuracy: Input accuracy + output accuracy
- Connection: Euro type connector terminal
- Construction: Small-sized front terminal structure
- DC Power input: Approx. 3 W
- Dielectric strength: 1500 V AC @1 minute (input to output to power to ground)
- Housing material: Flame-resistant resin (gray)
- Input accuracy: ±0.03 % of input range
- Insulation resistance: Greater than or equal to 100 M Omega with 500 V DC
- Isolation: Input to output to power
- Line voltage effect: ±0.1 % over voltage range
- Max. 55°C (131°F) for UL approval: Installation
- Mounting: DIN rail
- Operating humidity: 0 to 95 %RH (non-condensing)
- Operating temperature: -25 to +65°C (-13 to +149°F)
- Output accuracy: ±0.03 % of output range (When the output span is not more than 2 mA, add 0.1 % to the accuracy)
- Over-range output: -15 to +115 %
- Response time: 0.5 sec. + one pulse cycle or sampling time, whichever is larger (0 – 90%)
- Span adjustment: 85 to 115 % (front)
- Status indicator LED: Tri-color (green/amber/red) LED; Flashing patterns indicate operation status of the transmitter.
- Temp. coefficient: ±0.015%/°C (±0.008%/°F) of I/O range at -5 to +55°C [23 to 131°F]
- Weight: 100 g (3.53 oz)
- Zero adjustment: -15 to +15 % (front)
Applications
- None Available
Aliases