M-Systems M2XPA2 Mini-M Series Super-mini Signal Conditioner; Frequency Transmitter (PC Programmable) Simple Type: Signal Conditioning
Signal conditioners convert a field signal from various sensors into standard signal suitable for processing in PLC, DCS or PC-based systems. They are also used to boost a signal to increase load drive capability, to isolate a signal to stop ground loops. More than 75000 combinations of process signal I/O, power input and mounting configuration are selectable. Additionally, M-System offers the broadest line of signal splitters available. M2 Series Signal Conditioners are designed to accept a largest range of process signal inputs and provide a standard and non-standard DC output.
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval (selected models)
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
Specifications
- Accuracy: Input accuracy + output accuracy; Inversely proportional to the span
- Connection: M3 screw terminals (torque 0.8 N-m)
- Construction: Plug-in
- Dielectric strength: 2000 V AC @1 minute (input to output to power to ground)
- Housing Material: Flame-resistant resin (black)
- Input accuracy: ±0.03 % of the selected freq. range
- Isolation: Input to output to power
- Line voltage effect: ±0.1 % over voltage range
- Mechanical Contact Input amplitude: Min. 4 V, max. 12 V
- Mechanical Contact Maximum frequency: 0 – 10 Hz
- Mechanical Contact Sensing voltage / current: Approx. 12 V, 8 V or 4 V DC @1 mA
- Open Collector Input amplitude: Min. 4 V, max. 12 V
- Open Collector Maximum frequency: 0 – 100 kHz
- Open Collector Sensing voltage/ current: Approx. 12 V, 8 V or 4 V DC @1 mA
- Output accuracy: ±0.03 % of the selected output range
- Over-range output: Approx. -15 to +115 % at 1 – 5 V
- Pulse width time requirement: Min. 5 µsec., max. 10 sec
- Response time: Ts + Td (0 – 90 %)
- Span adjustment: 95 to 105 % (front)
- Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of I/O range at -5 to +55°C [23 to 131°F]
- Voltage Pulse Detecting levels: -2 – +4V
- Voltage Pulse Input amplitude: Min. 0.1 Vp-p, max. 100 Vp-p
- Voltage Pulse Input impedance: 10 kO min.
- Voltage Pulse Maximum frequency: 0 – 100 kHz
- Voltage Pulse Waveform: Square or sine
- Zero adjustment: -5 to +5 % (front)