M2SP - M-Systems M2SP Mini-M Series Super-mini Signal Conditioner; Low Frequency Transmitter...
Request Quote
For Price
- Part Number:
- M2SP
- Model Number:
- M2SP
- Make:
- M-SYSTEMS
- Lead Time:
- Available
- Qty In Stock:
- Available
M-Systems M2SP Mini-M Series Super-mini Signal Conditioner; Low Frequency Transmitter (50 Hz minimum) Simple Type: Signal Conditioning
Signal conditioners convert a field signal from various sensors into standard signal suitable for processing in PLC, DCS or PC-based systems. They are also used to boost a signal to increase load drive capability, to isolate a signal to stop ground loops. More than 75000 combinations of process signal I/O, power input and mounting configuration are selectable. Additionally, M-System offers the broadest line of signal splitters available. M2 Series Signal Conditioners are designed to accept a largest range of process signal inputs and provide a standard and non-standard DC output.
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval (selected models)
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
Specifications
- Accuracy: ±0.1 % (output 10 – 100 %)
- Connection: M3 screw terminals (torque 0.8 N-m)
- Construction: Plug-in
- DC Current: 0 – 20 mA DC
- DC VOLTAGE: 0 – 12 V DC
- Dielectric strength: 2000 V AC @1 minute (input to output to power to ground)
- Dry Contact: Mechanical contact or open collector
- Excitation: 12 V DC @30 mA; short-circuit protection
- FREQUENCY RANGE: 0 – 50 Hz through 10 kHz
- Housing Material: Flame-resistant resin (black)
- Input Filter: Provided with input range <100 Hz (time constant approx. 1 msec.)
- Input impedance: 10 kO min
- Input pulse sensing: DC coupled; detecting pulse rise
- Isolation: Input to output to power
- Line voltage effect: ±0.1 % over voltage range
- Load resistance: Output drive 1 mA max.; at
- Low-end cutout: 2 to 5 %
- Minimum span: 5 mV
- Offset: Max. 1.5 times span
- Over-range output: 0 to 120 % at 1 – 5 V
- Pulse width time requirement: 20 µsec. min. for high and low levels
- Ripple: 0.2 %p-p max. with input
- Sensing: Approx. 12 V DC @3 mA
- Span adjustment: 95 to 105 % (front)
- Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
- Voltage Pulse: Square or sine waveforms
- Zero adjustment: -5 to +5 % (front)
Applications
- None Available
Aliases